USG

Power Module with Built-in GFCI
OJ Microline® intuitive Power Module with built-in GFCI
In large applications, UCG, UDG and UTN thermostats can be extended with additional USG power modules with built-in Class A GFCI. Output can thus be increased by 15 A per module.
EFFICIENT, INTUITIVE AND STYLISH
-
Easy to use with no need for use of manual
-
Screw terminals for safe and easy installation
-
Multi voltage: 120 - 240 V (incl. 208 V)
-
Output relay: 15 A
-
Class A GFCI: suitable for wet room installation
-
Industrial Design:
USA - Design Patent No. D768092
Canada - Design Patent No. 161353
-
Product Sheet
-
Guide
-
Brochure
-
Where to connect the ground wire of floor mats?
Reply
The ground wire in the floor mat must be connected directly to the ground wire of the supply.
-
What is the recommended night setback?
Reply
The recommended night setback is max 5°C/41°F
-
Does the adaptive function reset when making a factory reset?
Reply
Yes the adaptive function is reset during a factory reset.
-
Installation – Length of sensor cable
Question
What is the maximum length of the sensor cable?
Answer
In general, it is recommended that the maximum sensor cable length should be 164 feet/50 meters, the length might be shorter. Read the instructions for the precise maximum length.
-
How can I cure the E2 error message?
Reply
"E2" means defective, damaged or disconnected floor sensor. Sensor resistance should be 10 or 12 kOhm at 25°C (77°F). The onstruction or quick guide holds informatiom for the specific thermostats.
Our Brand

Know How Creates is our promise to you: we use our insight and expertise to find the right solution.
News

Find the latest HVAC News from OJ Electronics here.
Green Comfort

Intelligent control results in maximum comfort with low energy consumption.
Contact

Dialogue and close cooperation is the shortest way to a perfect solution.