Clock Thermostat OCD2 Clock Thermostat OCD2. OCD2 has built-in clock function, is provided 4-event program and includes both: built-in and limitation floor sensor. The thermostat operates either with one of these sensors or with both of them. OCD2 can be programmed for individual needs and therefore is the best choice for obtaining high comfort at the minimum energy consumption.

4-Event OJ Microline®
- Clock Thermostat OCD2

OCD2 has built-in clock function and is provided 4-event program for automatic temperature control. The thermostat has adaptive function meaning the thermostat calculates when the heating has to be switched on to make sure that the comfort temperature is obtained at the required time. All settings and the clock are maintained if the thermostat is switched off by the built-in interrupter.

  • Min. temperature limitation: For better heating comfort
  • Max. temperature limitation: Protection of i.e. wooden floors
  • 4-event Clock thermostat with 2 sensors
  • Built in room sensor and floor sensor

 

 

 

Related
Products
FAQ
  • How to tell whether it is an OCC2 or OCD2 thermostat?

    Reply

    • Press both UP and DOWN buttons together for 3 seconds. INFO is displayed.
    • Press UP button until you reach the "APP" sub menu. Select the sub menu with the OK button.
    • Try changing application type. If "roLi" is available the thermostat is a OCD2
  • Why does the thermostat keep clicking on and off rather than heating up?

    Question

    We have a OCC2 for under floor bathroom heating. The thermostat / clock keeps clicking on and off every few seconds, when it is supposed to be heating up. The display goes blank and then reappears with an audible click for a few seconds. What is happening?

    Reply

    The internal power supply of the thermostat has over the years deteriorated. Please contact your local dealer for replacement.

  • What is the backup time on the OCC2?

    Reply

    The backup time on the OCC2/OCD2 is 48 hours.

  • What does error code "E2" mean?

    Reply

    Error code "E2" means defective, damaged or not connected floor sensor. Check connections or replace sensor if necessary.

  • What is the recommended night setback?

    Reply

    The recommended night setback is max 5°C/9°F

     

     

  • Does the adaptive function reset when making a factory reset?

    Reply

    Yes the adaptive function is reset during a factory reset.

     

     

  • Where to connect the ground wire of floor mats?

    Reply

    The ground wire in the floor mat must be connected directly to the ground wire of the supply.

  • What is the maximum lenght of the sensor cable?

    Reply

    In general, we recommend a maximum cable length of 50 meters, the lenght might be shorter. Read the instructions for the precise maximum lenght.

  • How can I cure the E2 error message?

    Reply

    "E2" means defective, damaged or disconnected floor sensor. Sensor resistance should be 10 or 12 kOhm at 25°C (77°F). The onstruction or quick guide holds informatiom for the specific thermostats.

Our Brand

Know How Creates
Know How Creates

Know How Creates is our promise to you: we use our insight and expertise to find the right solution.

News

Floor Heating Electric
FHEL News

Find the latest Floor Heating Electric News from OJ Electronics here.

Green Comfort

Intelligent Control
Green Comfort

Intelligent control results in maximum comfort with low energy consumption.

Contact

OJ Electronics
Contact OJ Electronics

Dialogue and close cooperation is the shortest way to a perfect solution.